KNX Metering Gateway Modbus - MTN6503-0201

Hover over image to zoom

  • Image 1
Schneider
£258.78 (inc VAT) £215.65 (exc VAT)
SKU:
MTN6503-0201
Weight:
0.20 KGS
Availability:
5 - 10 days lead time

 Product Description

The KNX Metering Gateway Modbus REG-K is a gateway between a Modbus installation and the KNX bus.
The device transmits measured power and consumption values from connected Modbus power counters to the KNX bus. These power counter data can be used to evaluate, visualise, or reduce the power consumption in your KNX installation.
Up to ten Modbus counters can be connected to the gateway in parallel with RTU transfer protocol. These counters send data to the KNX via the gateway. The gateway always works in master mode, and the connected Modbus devices work in slave mode.
Communication from KNX to the Modbus is not possible.
The ETS application has pre-programmed templates for 17 different Schneider Electric models of Modbus counters. In ETS, a corresponding template can be assigned to each connected Modbus counter. The corresponding Modbus registers are then automatically assigned to the communication objects on the KNX side.

The following models of Schneider Electric Modbus counters are supported:
- PM9C universal meter
- PM210 universal meter
- PM710, PM750 universal meters
- PM810, PM820, PM850, PM870 universal meters
- PM1200, PM6200 universal meters
- iEM3150, iEM3155, iEM3250, iEM3255 energy counters
- PM3250, PM3255 universal meters
- SIM10M Smart Interface Module

For Modbus devices without a template, up to 40 Modbus registers can be directly assigned to the communication objects on the KNX side.

The device is supplied with power via the KNX bus.
With integrated bus coupler.
For installation on DIN rails TH35 according to EN 60715.
The bus is connected using a bus connecting terminal.
With screw terminals.

KNX software functions:
Modbus communication settings (baud rate, parity, delays).
Selection of pre-programmed templates for 17 Modbus counters with detection of: voltage (phase 1-3), current (phase 1-3), frequency, power factor, active power, reactive power, apparent power, active energy, reactive energy, 6 binary counters, 2 analogue inputs (using Smart Interface Module SIM10M template).
In addition to the template, direct access to Modbus registers and manual assignment of the register values to communication objects are possible.
Diagnostic function: active and passive evaluation of errors in the Modbus installation.
All values can be reset by a reset object.
Device width: 2.5 modules = approx. 44 mm

Technical Details

range of product SpaceLogic KNX
product or component type Metering gateway
bus type KNX / Modbus
connections - terminals Modbus: screw terminals / KNX: bus terminal
total number of 18 mm modules 2
mounting support DIN rail
[Ue] rated operational voltage 24 V
IP degree of protection IP20

 

Downloads

User Guide

KNX- Metering Gateway Modbus REG-K-Operating instructions (EN) (Version 0)

System User Guide

KNX- Metering Gateway Modbus REG-K-ETS Software Description (EN) (Version 0)

Technical Leaflet

KNX Metering Gateway Modbus REG-K-Technical leaflet (Version 1.0)

Software - ETS

MTN6503-0201 Software ETS4-ETS5.x (knxprod) (Version V1.0)

 Find Similar Products by Category

 Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

You Recently Viewed...

 

What's News

newsletter

I would like to receive occasional newsletters regarding new products and promotions.

Follow us on

Copyright 2024 Home of Technologies Limited. All Rights Reserved.
 Sitemap | Our Privacy Policy | Store devoleped and designed by Home of Technologies marketing department

Click the button below to add the KNX Metering Gateway Modbus - MTN6503-0201 to your wish list.